SERVICE

 Global Lift Solution proves value beyond technology
 through true professional expertise. 

Visualizing complex disaster scenarios step by step,  
we identify safe evacuation routes 
  

  Fire Evacuation Simulation  


 As buildings become taller and underground spaces become more complex and integrated, evacuation routes during a fire become increasingly complicated. 

 GLS Co., Ltd. scientifically compares and analyzes smoke spread rates and occupant evacuation times through 3D simulations that replicate real fire scenarios. 


 Rather than vague predictions, we verify whether the 'Available Safe Egress Time (ASET)' sufficiently exceeds the 'Required Safe Egress Time (RSET)',
 helping to establish a complete fire evacuation system that aims to reduce casualties to zero. 


Why is this service necessary?  
  Securing the Golden Time  

 Quantitatively verifies the available time for all occupants to evacuate before smoke accumulation, maximizing survival probability. 

Bottleneck Mitigation

We identify in advance high-risk areas where crowd congestion under panic conditions may lead to crushing accidents, and improve them through structural redesign.

Performance-Based Design Verification

We validate actual evacuation performance by applying fire safety performance-based design tailored to the specific characteristics of the building.


Step-by-step consulting support  
Step-by-step consulting support  
❶ Fire and Spatial Modeling  

• 3D implementation of architectural drawings  

• Definition of high fire-risk zones based on the placement of combustible materials, etc.  

❷ Complex Scenario Setup  

• Incorporation of ignition points, smoke spread direction, occupant density, and psychological panic conditions  

• Design of multiple evacuation scenarios based on worst-case conditions  

❸ Establishing Optimal Evacuation Strategies  

• Comparative analysis of ASET (Available Safe Egress Time) and RSET (Required Safe Egress Time)  

• Analysis of vulnerable zones with risk of suffocation or isolation  

• Proposal of improvement measures such as widening bottleneck passages, adding emergency exits, and installing evacuation guidance lines  