SERVICE

Global Lift Solution proves the value beyond technology
through expertise.

When an Elevator Stops
Without a Mechanical Fault,

The Cause Lies in the Power Supply

Power & Communication Quality Diagnostics


If unexplained errors and unexpected shutdowns continue even after component replacement and mechanical repairs,
it's time to look beyond the mechanical system.
Modern elevators are sophisticated electronic systems built with thousands of precision semiconductor components.
Invisible power noise, harmonic distortion, and communication instability are often the root causes of control system malfunctions.


GLS is the only elevator design and supervision consulting firm in Korea capable of providing both power quality and communication quality diagnostics.
Going beyond mechanical engineering, we deliver electrical and electronic engineering solutions to resolve failures that others cannot.


Why Power Quality Diagnostics?

Three-Phase Power Quality Logger 

Identifying communication errors caused by electrical noise

and floor indicator malfunctions.

High-Performance Oscilloscope 

Resolving intermittent "ghost faults"

that occur without any mechanical cause.

Digital Multimeter 

Resolving operational errors caused by

power interruptions, voltage sags, and harmonic distortion.

Many facilities waste valuable budgets by focusing solely on mechanical component replacement.

GLS delivers precise power and communication quality diagnostics using advanced measurement equipment and industry-leading expertise.


Key Diagnostic Areas
❶ Precision Power Quality Diagnostics

Evaluates the integrity of the elevator power supply
to identify conditions that can critically affect the control system.

Harmonic Analysis

Evaluates the impact of harmonic currents generated by inverters and other equipment on surrounding electrical systems.

Voltage Stability Assessment

Measures voltage sags, swells, and voltage unbalance to evaluate power supply stability.

Grounding & Leakage Current Assessment

Analyzes grounding resistance and unwanted leakage currents to identify the risk of electric shock and system malfunctions.

❷ Communication Quality & Noise Diagnostics

Analyzes communication signals between the control panel, elevator car, and hall buttons

to identify the causes of data loss and communication errors.

Communication Line Noise Measurement

Analysis of electromagnetic interference (EMI/EMC) affecting the control panel communication lines

Bit Error Rate (BER) Inspection

Diagnoses communication and command errors caused by signal distortion

❷ Communication Quality & Noise Diagnostics

Analyzes communication signals between the control panel, elevator car, and hall buttons
to identify the causes of data loss and communication errors.

Communication Line Noise Measurement

Analyzes electromagnetic interference (EMI/EMC) affecting the control panel communication lines 

Bit Error Rate (BER) Inspection

Diagnoses communication and command errors caused by signal distortion

Copyright © 2026 GLS All rights reserved.